TRAY & POWER CABLES

TRAY CABLERW90/ServiceCPE®1,000 Volt Copper3 Conductor

Description

Three copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type USE-2 or RW90 1kV), phase identified and cabled together with fillers (when necessary) and bare copper ground conductor. Cable core covered with binder tape and overall black CPE jacket. Available with tinned conductors.

Application

Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2

Standards

UL 1277, CSA C22.2 #230 TC
ICEA S-95-658/NEMA WC-70
Exposed Runs Rated (TC-ER)
IMSA 19-1 (K-1 Colors)
Flame Rated: IEEE 383 (70,000 BTU),
      
T-29-520 (210,000 BTU) (available upon request),
       IEEE 1202/CSA FT-4 (available upon request),
       Two-hour Firewall
Temperature Rated at 90°C Wet/Dry
Sunlight and Oil Resistant I Jacket
Direct Burial
Color Code: Method 4
       K-2 (#14 AWG - #10 AWG)
       (optional color codes available)

RoHS Compliant

VIEW PRODUCT DATA TABLE

 

Part Number

 

 

Size

(AWG or Kcmil)

 

Strand

(no.)

 

Insulation

Thickness

(mils)

 

Grounding

Conductor

(AWG)

 

Jacket

Thickness

(mils)

Approx.

Diameter Overall

(in.)

 

Approx.

Net Weight

(lb./1000')

 

Ampacity*

(30°C ambient) 90°C Wet/Dry

TCC14/3UG

14

  7

  45

14

  45

0.44

   111

    25†

TCC12/3UG

12

  7

  45

12

  45

0.48

   150

    30†

TCC10/3UG

10

  7

  45

10

  60

0.56

   221

    40†

TCC8/3UG

8

  7

  60

10

  60

0.69

   315

  55

TCC6/3UG

6

  7

  60

  8

  60

0.79

   483

  75

TCC4/3UG

4

  7

  60

  8

  80

0.93

   704

  95

TCC3/3UG

3

  7

  60

  6

  80

0.99

   857

115

TCC2/3UG

2

  7

  60

  6

  80

1.05

1,016

130

TCC1/3UG

1

19

  80

  6

  80

1.21

1,274

145

TCC1/03UG

1/0

19

  80

  6

  80

1.29

1,537

170

TCC2/03UG

2/0

19

  80

  6

  80

1.39

1851

195

TCC3/03UG

3/0

19

  80

  4

  80

1.49

2,283

225

TCC4/03UG

4/0

19

  80

  4

  80

1.62

2,773

260

TCC250/3UG

250

37

  95

  4

110

1.82

3,320

290

TCC350/3UG

350

37

  95

  3

110

2.03

4,429

350

TCC500/3UG

500

37

  95

  2

110

2.30

6,093

430

TCC600/3UG

600

61

110

  2

110

2.52

7,249

475

TCC750/3UG

750

61

110

  1

110

2.69

8,854

535

*Per NEC Table 310.15 (B)(16). †The overcurrent protection for items marked with an obelisk  (†) shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC 310-16 footnote. NOTE: The data shown is approximate and subject to standard industry tolerances.

Related Products

TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®
  • 600/1,000 Volt Copper
  • 4 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®
  • 600/1,000 Volt Copper
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®, Shielded
  • 600/1,000 Volt Copper
  • 3 or 4 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®, Shielded
  • 600/1,000 Volt Copper
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®
  • 600/1,000 Volt Copper, LSZH Jacket
  • 3 Conductor, Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®
  • 600/1,000 Volt Copper, LSZH Jacket
  • 4 Conductor, Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus® 50% Ground
  • 600/1,000 Volt Copper, LSZH Jacket
  • 3 Conductor, Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®
  • 600/1,000 Volt Copper, LSZH Jacket
  • Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®, Shielded
  • 600/1,000 Volt Copper, LSZH Jacket
  • 3 or 4 Conductor, Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®, Shielded
  • 600/1,000 Volt Copper, LSZH Jacket
  • Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC
  • 600/1,000 Volt Copper
  • 3 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC
  • 600/1,000 Volt Copper
  • 4 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC
  • 600/1,000 Volt Copper
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC, Shielded
  • 600/1,000 Volt Copper
  • 3 or 4 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC, Shielded
  • 600/1,000 Volt Copper
 

REQUEST QUOTE