ARMORED CABLE

JACKETED MC

ACW90/ACWU90, 50% Ground

600 Volt Copper

4 Conductor

Description

4 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type RW90), phase identified and cabled with suitable fillers (when necessary) and bare copper ground conductor (3 segmented grounds). Cable core covered with binder tape and galvanized steel interlocked armour, with black PVC jacket. Jacket available in colours.

Application

Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2

Standards

UL 1569
ICEA S-95-658/NEMA WC-70
Flame Rated: CT Use, IEEE 383 (70,000 BTU), ICEA T-29-520
       (210,000 BTU), IEEE 1202/CSA FT-4, Two-hour Firewall
Temperature Rated at 90°C Wet/Dry
Cold Temperature Rated at -25°C
Sunlight and Oil Resistant II Jacket
Direct Burial (includes encasement in concrete)
Color Code: Method 4 (K2 on #8; other color codes available)
RoHS Compliant

ISOROHSUSAREACH
VIEW PRODUCT DATA TABLE

Part Number

 

Size

(AWG or Kcmil)

Strand

(no.)

Insulation

Thickness

(mils)

Grounding

Conductors

(AWG)

Diameter

Over Armour

(in.)

PVC Jacket

Thickness

(mils)

Approx.

Diameter Overall

(in.)

Approx.

Net Weight

(lb/1000')

Ampacity*

(30°C ambient) 90°C Wet/Dry

GAP6/4G3#12

6

  7

45

3-#12

0.87

50

0.97

778

75

GAP4/4G3#10

4

  7

45

3-#10

0.99

50

1.09

1,077

95

GAP3/4G3#10

3

  7

45

3-#10

1.05

50

1.15

1,248

115

GAP2/4G3#8

2

  7

45

3-#8

1.13

50

1.23

1,515

130

GAP1/4G3#8

1

19

55

3-#8

1.33

50

1.43

1,933

145

GAP1/04G3#6

1/0

19

55

3-#6

1.43

50

1.53

2,379

170

GAP2/04G3#6

2/0

19

55

3-#6

1.51

60

1.63

2,829

195

GAP3/04G3#4

3/0

19

55

3-#4

1.65

60

1.77

3,500

225

GAP4/04G3#4

4/0

19

55

3-#4

1.79

60

1.91

4,167

260

GAP250/4G3#4

250

37

65

3-#4

1.99

60

2.11

4,883

290

GAP300/4G3#3

300

37

65

3-#3

2.13

60

2.25

5,743

320

GAP350/4G3#2

350

37

65

3-#2

2.25

75

2.40

6,667

350

GAP400/4G3#2

400

37

65

3-#2

2.35

75

2.50

7,381

380

GAP500/4G3#1

500

37

65

3-#1

2.53

75

2.68

8,984

430

GAP600/4G3-1/0

600

61

80

3-1/0

2.85

75

3.00

10,795

475

GAP750/4G3-2/0

750

61

80

3-2/0

3.05

85

3.22

13,209

535

*Per NEC Table 310.15 (B)(16). Four-conductor ampacity assumes three are hot and one is neutral. NOTE: The data shown is approximate and subject to standard industry tolerances.