SINGLE CONDUCTORS

SERVICEPRO-X®XHHW-2600/1,000 Volt Copper, VW-1, CT RatedNo Pulling Lubricant Required

Description

Single copper conductor, stranded and insulated with moisture, heat, and flame resistant, chemically crosslinked polyethylene. Featuring ServicePRO-X® Insulation–No Pulling Lubricant Required (#6 AWG and larger). Available in colors.

Application

Suitable for general purpose wiring, power distribution, and branch circuit wiring where a cable having superior flame retardance is required. Suitable for use in 105°C dry systems. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade).

Standards

ASTM Standards: B-3 (soft or annealed), B-8 (concentric lay stranded),
       B-787 (combination strand)
UL 44
ICEA S-95-658/NEMA WC-70
Federal Spec. A-A-59544
Flame Rated: VW-1 (all sizes), CT Use/IEEE 1202 (1/0 AWG and larger),
       FT-4 (1/0 AWG and larger)
Temperature Rated at 90°C Wet/Dry, Cold Temperature Rated at -40°C
Sunlight Resistant (#6 AWG and larger), Gasoline and Oil Resistant II
Appliance Wiring Material: Style 3578
RoHS Compliant

 

View Product Data Table

Part Number

 

Size

(AWG or Kcmil)

Strand

(no.)

Insulation Thickness

(mils)

Nominal Diameter Overall

(in.)

Approx. Net Weight

(lb./1000')

Ampacity*

90°C Wet/Dry

XHVW14BK

14

  7

30

0.133

    19

      35†

XHVW12BK

12

  7

30

0.152

    28

      40†

XHVW10BK

10

  7

30

0.175

    41

      55†

XHVW8BK

8

  7

45

0.233

    66

    80

XHVW6BK

6

  7

45

0.271

  102

  105

XHVW4BK

4

  7

45

0.320

  155

  140

XHVW3BK

3

  7

45

0.344

  185

  165

XHVW2BK

2

  7

45

0.374

  238

  190

XHVW1BK

1

19

55

0.426

  301

  220

XHVW1/0BK

1/0

19

55

0.467

  374

  260

XHVW2/0BK

2/0

19

55

0.512

  465

  300

XHVW3/0BK

3/0

19

55

0.560

  579

  350

XHVW4/0BK

4/0

19

55

0.619

  723

  405

XHVW250BK

250

37

65

0.702

  850

  455

XHVW300BK

300

37

65

0.759

  997

  500

XHVW350BK

350

37

65

0.806

1,173

  570

XHVW400BK

400

37

65

0.851

1,314

  615

XHVW500BK

500

37

65

0.926

1,651

  700

XHVW600BK

600

61

80

1.047

1,972

  780

XHVW750BK

750

61

80

1.145

2,444

  885

*Per NEC Table 310.15 (B)(17). †The overcurrent protection for items marked with an obelisk (†) shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC 310-17 footnote. NOTE: The data shown is approximate and subject to standard industry tolerances.

 

REQUEST QUOTE