Dual Rated Tray Cable

Underwriters Laboratory (UL) recently updated its standard for electrical power and control tray cable, allowing manufacturers to market tray cable as UL dual rated for 600V/1kV applications.

Tray Cable - XHHW-2 or RW90/PVC Circuit

Class B stranded, annealed copper conductors, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90) and phase identified. Cabled with fillers and binders (when necessary). Cable core covered with overall black PVC jacket.

Tray Cable - XHHW-2 or RW90/CPE Circuit

Class B stranded, annealed copper conductors, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 VW-1 or RW90 FT-1) and phase identified. Cabled with overall black CPE jacket.

Tray Cable - XHHW-2 or RW90/EnviroPlus (LSZH) Circuit

Conductors are stranded, annealed copper, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW- 2 or RW90) and phase identified. Cabled with fillers (when necessary). Cable core is covered with binder tape and an overall black zero halogen, limited smoke, zero lead jacket.

Tray Cable - XHHW-2 or RW90/PVC 3 Conductor

3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90) and phase identified. Cabled with fillers (when necessary) and bare copper ground conductor. Cable core covered with binder tape and overall black PVC jacket.

Tray Cable - XHHW-2 or RW90/PVC 4 Conductor

4 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90), phase identified and cabled with fillers (when necessary) and bare copper ground conductor. Cable core covered with binder tape, and overall black PVC jacket.

Tray Cable - XHHW-2 or RW90/CPE 3 Conductors

3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90) and phase identified. Cabled with fillers (when necessary) and bare copper ground conductor. Cable core covered with binder tape and overall black CPE jacket.

Tray Cable - XHHW-2 or RW90/CPE 4 Conductors

4 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90) and phase identified. Cabled with fillers (when necessary) and bare copper ground conductor. Cable core covered with binder tape and overall black CPE jacket.

Tray Cable - XHHW-2 or RW90/EnviroPlus (LSZH) 3 Conductors

3 conductors, stranded copper, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90) and phase identified. Cabled with fillers and bare copper ground conductor. Cable core is covered with binder tape and overall black zero halogen, limited smoke, zero lead jacket.

Tray Cable - XHHW-2 or RW90/EnviroPlus (LSZH) 4 Conductors

4 conductors, stranded copper, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90) and phase identified. Cabled with fillers and bare copper ground conductor. Cable core is covered with binder tape and overall black zero halogen, limited smoke, zero lead jacket.

Tray Cable - XHHW-2 or RW90/EnviroPlus (LSZH) 50% Ground

3 or 4 conductors, stranded copper, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90) and phase identified. Cabled with fillers and 3 bare copper ground conductors. Cable core is covered with binder tape and overall black zero halogen, limited smoke, zero lead jacket.

 