TRAY & POWER CABLE

TRAY CABLE

XHHW-2 or RW90/ServiceCPE®, Shielded

600 Volt Copper

3 or 4 Conductor

Description

3 or 4 stranded copper conductors, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2 or RW90) and phase identified. Cabled with fillers and bare copper ground conductor. Cable core is covered with binder tape, longitudinally applied corrugated copper tape shield, and overall black CPE jacket. Available with tinned conductors.

Application

Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2

Standards

UL1277, CSA C22.2 #230 TC
ICEA S-95-658/NEMA WC-70
Exposed Runs Rated (TC-ER)
IMSA 19-1
Flame Rated: IEEE 383 (70,000 BTU), IEEE 1202/CSA FT-4
       UL1685 and UL 1581, Two-hour Firewall
Temperature Rated at 90°C Wet/Dry
Cold Temperature Rated at -25°C
Sunlight and Oil Resistant I Jacket
Direct Burial
Color Code: Method 4, K-2 (#14 AWG - #8 AWG)
RoHS Compliant

ISORoHSUSAREACH
VIEW PRODUCT DATA TABLE

Part Number

 

Size

(AWG)

Strand

(no.)

Insulation

Thickness

(mils)

Grounding

Conductor

(AWG)

Jacket

Thickness

(mils)

Approx.

Diameter Overall

(in.)

Approx.

Net Weight

(lb./1000')

Ampacity*

(30°C ambient) 90°C Wet/Dry

TCCPESHC14/3G

14

  7

30

14

45

0.40

   134

    25†

TCCPESHC12/3G

12

  7

30

12

45

0.44

   175

    30†

TCCPESHC10/3G

10

  7

30

10

45

0.49

   233

    40†

TCCPESHC8/3G

  8

  7

45

10

60

0.64

   347

  55

TCCPESHC6/3G

  6

  7

45

  8

60

0.72

   505

  75

TCCPESHC4/3G

  4

  7

45

  8

80

0.87

   729

  95

TCCPESHC2/3G

  2

  7

45

  6

80

0.99

1,045

130

TCCPESHC1/3G

  1

19

55

  6

80

1.10

1,274

145

 

TCCPESHC14/4G

14

  7

30

14

45

0.43

   158

    25†

TCCPESHC12/4G

12

  7

30

12

45

0.48

   208

    30†

TCCPESHC10/4G

10

  7

30

10

60

0.56

   295

    40†

TCCPESHC8/4G

  8

  7

45

10

60

0.70

   426

  55

TCCPESHC6/4G

  6

  7

45

  8

60

0.79

   618

  75

TCCPESHC4/4G

  4

  7

45

  8

80

0.95

   903

  95

TCCPESHC2/4G

  2

  7

45

  6

80

1.08

1,309

130

*Per NEC Table 310.15 (B)(16). Four-conductor ampacity assumes three are hot and one is neutral. †The overcurrent protection for items marked with an obelisk (†) shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG and 30 amps for #10 AWG per NEC 310-16 footnote. NOTE: The data shown is approximate and subject to standard industry tolerances.

Related Products

 Rep Login

 

CONTACT US

Your Name:

Email:

Location (Zip Code):

Company:

Market:

Message: